Gases to be purified
Info:
|
|
|
Clean Dry Air (CDA) & Oxygen Ambient Temperature Purification
Impurities removed can include H 2O, CO, CO 2, NMHC, Acids, Bases, Organics, and Refractory Compounds. Impurities in these gases are reduced to less than 1 part-per-billion, in most cases. (For CH 4 removal, see our MonoTorr product line.)
Model Number Configuration (Example MC1-202FV)
MC1 |
-202 |
-FV |
Model Size |
Media |
Options |
| |
|
Model Sizes
Media Types for Clean Dry Air
Media |
Gases Purified |
Impurities Removed |
Regenerable |
202 |
CDA, O2 |
H2O < 1ppb |
Yes |
203 |
CDA, O2 |
H2O, CO2 < 100 ppt Acids, Organics, Refractory compounds < 1 ppt Bases < 5 ppt |
Yes |
403 |
CDA, O2 |
Acids, Organics, Refractories < 1 ppt Bases < 5 ppt |
No |
404 |
CDA, O2 |
Organics < 1 ppb |
Yes |
906 |
CDA, O2 |
H2O, CO, CO2, NMHCs< 1 ppb |
Yes |
Options
Option |
Description |
Comments |
F |
0.003 μm filter option |
If not ordered, 2 µm filter standard |
HF |
0,003 μm high-flow filter option |
For use with MC4500 model only |
V |
Inlet and outlet valves |
1/4" or 1/2" Manual diaphragm Valves |
|