PS14 Ambient Gas Dryers and Purifiers



The PS14 Series MegaTorr purifiers are portable, low maintenance units, that operate at room temperature without the need for utilities. Because impurities are removed at ambient temperature, the PS14 continues to purify even with a complete loss of on-site power.
The PS14 series is available with two purification media's:
-H2O Removal Only (MD Model)
-H2O, CO, CO2, H2, O2 Removal (MN Model)
Single column (SC) or dual column (DC) configurations are available. With the dual column configuration one or both columns can be used at a time. All PS14 purifiers must be returned back to the factory for regeneration. Please contact the factory for information on the lifetime of the PS14 Purifier. Available options include mass flow meter, pressure measurement, high temperature safety shutdown and ultrafine 0.003 micron particle filter.

PS14 Performance
Gases PurifiedImpurities RemovedImpurities RemovedOutlet Performance
Dryer Only (MD)Standard Unit (MN)
N2, Rare GasesH2OH2O, CO, CO2, H2, O2< 1 ppb
CDA, O2H2ON/A< 1 ppb
H2H2OH2O, CO, CO2, O2< 1 ppb

PS14 Performance - Single Column (SC)
ModelImpurities RemovedMaximum Flow
(Nm3/hr)
Maximum Pressure Drop
(bar)
Dimensions (cm)Weight
(kg)
HWD
PS14-MD10-SCH2O20011967166364
PS14-MD18-SCH2O10001196188114364
PS14-MD25-SCH2O10001234127102635
PS14-MD38-SCH2O500012161551862000
PS14-MN10-SCH2O, CO, CO2, H2, O220011967166364
PS14-MN18-SCH2O, CO, CO2, H2, O210001196188114364
PS14-MN25-SCH2O, CO, CO2, H2, O210001234127102635
PS14-MN38-SCH2O, CO, CO2, H2, O2500012161551862000

PS14 Performance - Dual Column (DC)
ModelImpurities RemovedMaximum Flow
(Nm3/hr)
Maximum Pressure Drop
(bar)
Dimensions (cm)Weight
(kg)
HWD
PS14-MD10-DCH2O200120615889500
PS14-MD18-DCH2O10001240230921200
PS14-MD25-DCH2O100012642541022300
PS14-MD38-DCH2O500012681522442272
PS14-MN10-DCH2O, CO, CO2, H2, O2200120615889432
PS14-MN18-DCH2O, CO, CO2, H2, O210001240230921200
PS14-MN25-DCH2O, CO, CO2, H2, O2100012642541022300
PS14-MN38-DCH2O, CO, CO2, H2, O2500012681522442272


PS14 purifier with dual columns (DC). Purifier is shown with optional auto-safety system to protect columns from overtemperature conditions.

PS14 Single Column purifier shown with isolation valves and optional moisture monitor to provide notification of moisture breakthrough.

PS14-MN10-SC Purifier

© 2022 Rainer Lammertz